Error: -2147024888 Not enough Storage us available to process this command (-2147024888 0X80070008) when clicking on the binocular icon

This article applies to the following products:
     Messageware AttachView 8.6

 

SYMPTOM

 

User receive the following error message when clicking on binocular icon

 

“Error: -2147024888 Not enough Storage us available to process this command (-2147024888 0X80070008)”  

 

CAUSE

 

            This behavior occurs if the temp folder used for storing converted files has become corrupted.

 

 

RESOLUTION

 

Follow the steps below to change the path for temporary and converted files in AttachView administrative console

 

1.     Created another temporary folder temp2 on X: ( where X is the local drive)

2.     Verify that Everyone group has access to the this folder

3.     Verify that Everyone group has Full Control permission set to allow

4.     On the Exchange Server, open up the AttachView Administrative Console

5.     Navigate to Global Settings > Path

6.     Select following Path for temporary files Browse to X:\temp2

7.     Select following Path for converted files Browse to X:\temp2

8.     Click ok and apply

9.     Restart the World Wide Web Publishing Services

 

This article applies to the following products:
     Messageware AttachView 8.6